Therapeutic protein in a solid delivery system

Stablisation of a therapeutic protein in a sold delivery systemPartner: a company with an innovative needle-free delivery system, which is used to inject solid doses subcutaneously.

Problem: a therapeutic protein required exposure to ionising radiation, which is typically used in the sterilisation of medical devices. This irradiation, however, severely damaged the protein, as shown by reverse-phase high-performance liquid chromatography (HPLC).

Strategy: Arestat-R™ technology was used to stabilise the protein.

Results:

Last updated: 13 June 2008